Ascend Pipeline Guida Utente Pagina 86

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 85
Configuring IP Routing
Configuring IP routing connections
2-36 Preliminary January 30, 1998 Pipeline User’s Guide
IP options...
LAN Adrs=10.7.8.200/24
RIP=Off
3
Close and save the profile.
4
Open the Ethernet > Static Rtes > Default profile.
5
Set these parameters:
Active=Yes
Gateway=10.4.4.133/24
Metric=1
Preference=100
Private=Yes
6
Close and save the profile.
On the site B router:
7
Open Ethernet > Connection > profile for site A.
8
Set these parameters:
Station=MAXA
Active=Yes
Encaps=MPP
Route IP=Yes
Encaps options...
Send Auth=CHAP
Recv PW=*SECURE*
Send PW=*SECURE*
IP options...
LAN Adrs=10.4.5.1/24
RIP=Off
9
Close and save the profile.
10
Open the Ethernet > Static Rtes > Default profile on the site B Pipeline.
11
Set these parameters:
Active=Yes
Gateway=10.4.5.1/24
Metric=1
Preference=100
Private=Yes
Vedere la pagina 85